--- title: "3. Bayesian calibrations and reconstructions" output: rmarkdown::html_vignette vignette: > %\VignetteIndexEntry{3. Bayesian calibrations and reconstructions} %\VignetteEngine{knitr::rmarkdown} %\VignetteEncoding{UTF-8} --- This vignette covers Bayesian calibrations in `bayclumpr`. We fit the models, choose priors, check convergence, compare models, and reconstruct temperatures. If you're new to the package, start with `vignette("bayclumpr", package = "bayclumpr")`. ``` r library(bayclumpr) ``` ## The four models `cal.bayesian()` fits up to four models. They cover every combination of two choices: whether measurement errors are used, and whether intercepts and slopes vary by `Material`. We choose them with the `models` argument. | `models` | Name in the result | Measurement errors | Varies by `Material` | |:---------|:-------------------|:------------------:|:--------------------:| | `"errors"` | `BLM1_fit` | Yes | No | | `"noerrors"` | `BLM1_fit_NoErrors` | No | No | | `"mixed_errors"` | `BLM3_fit_Errors` | Yes | Yes | | `"mixed_noerrors"` | `BLM3_fit` | No | Yes | Models with measurement errors use `TempError` and `D47error` for each observation. All models estimate `sigma`, the scatter around the calibration line. With measurement errors, `sigma` is the scatter left after removing the measurement error in `D47`. Without them, it includes the measurement error. Mixed models let intercepts and slopes vary by `Material` around shared means. They need at least two materials and are skipped otherwise. The models run in Stan. If they weren't compiled when `bayclumpr` was installed, the first fit of each model in a session compiles it. This can take a minute or more. Later fits in the same session start right away. ## Fitting a model We simulate 50 observations under the intermediate error scenario. The true values are `alpha` = 0.268 and `beta` = 0.0369. ``` r set.seed(3) ds <- cal.dataset(error = "S2", nobs = 50) ``` We start with the errors model: ``` r fit <- cal.bayesian(calibrationData = ds, models = "errors") #> Compiling the Stan model errors. This happens once per session and can take a minute or two. fit #> Bayesian clumped isotope calibration #> Priors: alpha ~ N(0.231, 0.065), beta ~ N(0.039, 0.004) #> #> BLM1_fit #> parameter estimate SE median lower upper ESS Rhat #> alpha 0.25881 0.020695 0.25869 0.21710 0.29843 4058 0.9997 #> beta 0.03750 0.001717 0.03749 0.03419 0.04095 3997 0.9995 #> sigma 0.02463 0.002906 0.02439 0.01948 0.03066 4750 0.9991 #> #> Convergence #> model max_Rhat min_ESS divergences #> BLM1_fit 0.9997 3997 0 ``` The first table is the same summary given by `cal.summary()`. `estimate` is the posterior mean of each parameter and `SE` is its standard error, which is the SD of the posterior draws. `sigma` is itself an SD: the scatter of individual samples around the calibration line. `ESS` and `Rhat` show how well each parameter was sampled. The second table checks convergence for each model as a whole. We look for `max_Rhat` at or below 1.01, `min_ESS` of at least 100 per chain, and no divergences. `cal.bayesian()` gives a warning when a model fails any of these checks. When that happens, try a larger `numSavedSteps` and check the data for outliers or wrong units. ## Choosing priors The `priors` argument sets the priors on `alpha` and `beta`. There are three presets: | `priors` | `alpha` | `beta` | |:---------|:--------|:-------| | `"Informative"` | Normal(0.231, 0.065) | Normal(0.039, 0.004) | | `"Weak"` | Normal(0.231, 1) | Normal(0.039, 1) | | `"Flat"` | Flat | Flat | The informative values are the ones used in earlier versions of this package. Calibrations differ among reference frames and acid corrections, so check that these values suit your data. You can also set your own priors as a list with the mean and SD of each normal prior: ``` r myPriors <- list(alpha = c(0.25, 0.05), beta = c(0.038, 0.003)) ``` `cal.prior()` draws from a set of priors. This shows the range of slopes that a prior allows before seeing the data: ``` r quantile(cal.prior("Informative", n = 10000)$beta, c(0.025, 0.975)) #> 2.5% 97.5% #> 0.03105497 0.04668649 quantile(cal.prior(myPriors, n = 10000)$beta, c(0.025, 0.975)) #> 2.5% 97.5% #> 0.03203628 0.04367196 ``` Let's fit the same model under weak priors and compare the slopes: ``` r fitWeak <- cal.bayesian(calibrationData = ds, models = "errors", priors = "Weak") rbind( Informative = quantile(cal.draws(fit)$beta, c(0.025, 0.5, 0.975)), Weak = quantile(cal.draws(fitWeak)$beta, c(0.025, 0.5, 0.975)) ) #> 2.5% 50% 97.5% #> Informative 0.03419203 0.03748993 0.04094567 #> Weak 0.03260000 0.03677161 0.04075844 ``` ## Comparing models We can fit several models at once and compare them with `cal.compare()`. It uses approximate leave-one-out cross-validation. ``` r fits <- cal.bayesian(calibrationData = ds, models = c("errors", "noerrors")) #> Compiling the Stan model noerrors. This happens once per session and can take a minute or two. cal.compare(fits) #> model elpd_diff se_diff p_worse diag_diff diag_elpd #> BLM1_fit_NoErrors 0.0 0.0 NA #> BLM1_fit -0.1 0.1 0.89 N < 100 #> #> Diagnostic flags present. #> See ?`loo-glossary` (sections `diag_diff` and `diag_elpd`) #> or https://mc-stan.org/loo/reference/loo-glossary.html. ``` The best model is in the first row. When `elpd_diff` is small relative to `se_diff`, the data don't clearly favor one model. ## Mixed models To show the mixed models, we simulate a second material with D47 values that are 0.02 higher: ``` r ds1 <- cal.dataset(error = "S2", nobs = 50) ds2 <- cal.dataset(error = "S2", nobs = 50) ds2$D47 <- ds2$D47 + 0.02 ds2$Material <- 2 dsMixed <- rbind(ds1, ds2) fitMixed <- cal.bayesian(calibrationData = dsMixed, models = c("mixed_errors", "mixed_noerrors")) #> Compiling the Stan model mixed_errors. This happens once per session and can take a minute or two. #> Warning: There were 24 divergent transitions after warmup. See #> https://mc-stan.org/misc/warnings.html#divergent-transitions-after-warmup #> to find out why this is a problem and how to eliminate them. #> Warning: Examine the pairs() plot to diagnose sampling problems #> Compiling the Stan model mixed_noerrors. This happens once per session and can take a minute or two. #> Warning: There were 23 divergent transitions after warmup. See #> https://mc-stan.org/misc/warnings.html#divergent-transitions-after-warmup #> to find out why this is a problem and how to eliminate them. #> Warning: Examine the pairs() plot to diagnose sampling problems #> Warning: Bulk Effective Samples Size (ESS) is too low, indicating posterior means and medians may be unreliable. #> Running the chains for more iterations may help. See #> https://mc-stan.org/misc/warnings.html#bulk-ess #> Warning: Tail Effective Samples Size (ESS) is too low, indicating posterior variances and tail quantiles may be unreliable. #> Running the chains for more iterations may help. See #> https://mc-stan.org/misc/warnings.html#tail-ess #> Warning in .finish_fit(fits, prior, chains): Check convergence for: BLM3_fit_Errors, #> BLM3_fit. Print the result for details. fitMixed #> Bayesian clumped isotope calibration #> Priors: alpha ~ N(0.231, 0.065), beta ~ N(0.039, 0.004) #> #> BLM3_fit_Errors #> Material parameter estimate SE median lower upper ESS Rhat #> 1 alpha 0.26988 0.016214 0.26962 0.23926 0.30229 2692 1.0018 #> 1 beta 0.03747 0.001399 0.03748 0.03463 0.04016 2708 1.0017 #> 1 sigma 0.02435 0.001956 0.02421 0.02084 0.02837 3976 1.0006 #> 2 alpha 0.26863 0.021463 0.26867 0.22481 0.31017 2938 0.9994 #> 2 beta 0.03833 0.001765 0.03833 0.03483 0.04192 2946 0.9994 #> 2 sigma 0.02435 0.001956 0.02421 0.02084 0.02837 3976 1.0006 #> #> BLM3_fit #> Material parameter estimate SE median lower upper ESS Rhat #> 1 alpha 0.27035 0.016371 0.26990 0.23813 0.30256 2891 0.9995 #> 1 beta 0.03744 0.001407 0.03745 0.03462 0.04016 2947 0.9997 #> 1 sigma 0.02570 0.001887 0.02558 0.02224 0.02966 1739 1.0034 #> 2 alpha 0.26913 0.021344 0.26930 0.22539 0.31011 2812 0.9992 #> 2 beta 0.03828 0.001749 0.03827 0.03488 0.04184 2897 0.9993 #> 2 sigma 0.02570 0.001887 0.02558 0.02224 0.02966 1739 1.0034 #> #> Convergence #> model max_Rhat min_ESS divergences #> BLM3_fit_Errors 1.002 2692 24 #> BLM3_fit 1.003 1739 23 ``` The intercepts and slopes of the two materials are pulled toward shared means (partial pooling). The SDs among materials have half-normal priors with scales of 0.1 for the intercept at the mean calibration temperature and 0.01 for the slope. With fewer than five materials, these SDs mostly reflect their priors. ## Reconstructing temperatures `cal.draws()` returns the posterior draws of a model as a table. It has the same columns as the frequentist tables in `vignette("frequentist", package = "bayclumpr")`. ``` r draws <- cal.draws(fit) head(draws) #> alpha beta sigma #> 1 0.2913857 0.03403879 0.02635096 #> 2 0.2286358 0.03961537 0.02440160 #> 3 0.2765121 0.03592458 0.02101763 #> 4 0.2381617 0.03879429 0.02470852 #> 5 0.2492998 0.03765331 0.01982520 #> 6 0.2539153 0.03745754 0.02471296 ``` We create a reconstruction dataset and pass it to `rec.bayesian()` with the draws: ``` r recData <- data.frame( Sample = paste("Sample", 1:6), D47 = rep(c(0.6, 0.7, 0.8), 2), D47error = rep(c(0.005, 0.02), each = 3), N = 3 ) rec.bayesian(calModel = draws, recData = recData) #> Sample D47 D47error meanTemp SD SE median lower upper #> 1 Sample 1 0.6 0.005 59.169525 13.492686 12.919351 58.141071 36.176558 86.901763 #> 2 Sample 2 0.7 0.005 18.679092 8.878960 8.507950 18.238345 2.936739 36.380216 #> 3 Sample 3 0.8 0.005 -9.781490 6.594663 6.322624 -9.933485 -21.692635 3.210007 #> 4 Sample 4 0.6 0.020 59.489531 21.596755 16.403661 58.415102 30.709281 95.152623 #> 5 Sample 5 0.7 0.020 18.852540 14.311770 10.866998 18.135342 -0.351929 42.237888 #> 6 Sample 6 0.8 0.020 -9.734762 10.696587 7.841322 -10.021680 -24.568806 5.917603 ``` `meanTemp` is the posterior mean temperature in °C. `SE` is the standard error of the temperature, based on `D47error`, the standard error of the mean D47. `SD` is the uncertainty of the temperature of a single replicate, based on `D47error` × sqrt(`N`). `SD` is `NA` when the dataset has neither `N` nor `D47sd`. `median`, `lower`, and `upper` describe the 95% posterior interval, based on `SE`. Both `SD` and `SE` include the calibration, the scatter around the calibration line (`sigma`), and the error in `D47`. `rec.clumped()` gives the same kind of uncertainty with `prediction = TRUE`. `rec.bayesian()` doesn't run another MCMC. For each posterior draw, the temperature has a known distribution, so it's sampled directly. This takes less than a second. We can also pass the result of `cal.bayesian()` and name the model: ``` r rec.bayesian(calModel = fits, recData = recData, model = "noerrors") #> Sample D47 D47error meanTemp SD SE median lower upper #> 1 Sample 1 0.6 0.005 59.582528 13.850920 13.356362 58.760144 35.6641789 87.739793 #> 2 Sample 2 0.7 0.005 18.738866 9.209379 8.807402 18.453100 2.3154928 36.871627 #> 3 Sample 3 0.8 0.005 -9.680912 6.965055 6.621272 -9.908738 -22.0689063 3.782275 #> 4 Sample 4 0.6 0.020 59.743116 22.361167 16.759462 58.531780 30.6149554 95.806125 #> 5 Sample 5 0.7 0.020 19.093028 14.569364 10.940762 18.535532 -0.3365017 42.545939 #> 6 Sample 6 0.8 0.020 -9.661798 10.738637 8.158392 -10.011537 -24.7372205 6.941973 ``` ### Reconstructions with mixed models For mixed models, the reconstruction dataset needs a `Material` column with the same labels used in the calibration: ``` r recMixed <- data.frame( Sample = c("Sample 1", "Sample 2"), D47 = c(0.62, 0.62), D47error = 0.01, Material = c(1, 2) ) rec.bayesian(calModel = fitMixed, recData = recMixed, model = "mixed_errors") #> Sample D47 D47error meanTemp SD SE median lower upper #> 1 Sample 1 0.62 0.01 54.89756 NA 12.72386 54.08777 32.33342 82.54673 #> 2 Sample 2 0.62 0.01 58.08932 NA 13.09937 57.30202 34.82513 86.17134 ``` Mixed models can also reconstruct temperatures for a material that is not in the calibration. With `newMaterial = TRUE`, the intercept and slope are drawn from the shared means and the spread among materials. The intervals are wider, since we don't know where the new material falls among the others. ``` r recNew <- data.frame(Sample = "Sample 3", D47 = 0.62, D47error = 0.01) rec.bayesian(calModel = fitMixed, recData = recNew, model = "mixed_errors", newMaterial = TRUE) #> Warning in .rec_exact(draws, recData, ndraws, level = level): 27 draws had 10^6/T^2 at or #> below zero and were removed. #> Sample D47 D47error meanTemp SD SE median lower upper #> 1 Sample 3 0.62 0.01 60.44808 NA 62.03957 54.12968 9.942506 136.8542 ``` ## Tips for faster fits - Fit only the models you need with the `models` argument. - Run chains in parallel with `cores`, for example `cores = 4`. - Use fewer draws while you explore, for example `numSavedSteps = 1000`, and more for final results.